Segments:
Water throughput at | |||||
Utilized BECOPAD depth filter sheet | Nominal retention rate μm | Δ p = 100 kPa in l/m²/min | Δ p = 14.5 psi in gpm/ft² | Code Pre-filter layer | Code Main filter layer |
BECOPAD 115 C | 0.1 – 0.2 | 26 | 0.6 | A | 11 |
BECOPAD 120 | 0.1 – 0.3 | 55 | 1.3 | B | 12 |
BECOPAD 170 | 0.2 – 0.4 | 80 | 1.9 | C | 17 |
BECOPAD 220 | 0.3 – 0.5 | 100 | 2.5 | D | 22 |
BECOPAD 270 | 0.5 – 0.7 | 135 | 3.3 | E | 27 |
BECOPAD 350 | 0.7 – 1.0 | 160 | 3.9 | F | 35 |
BECOPAD 450 | 1.0 – 2.0 | 300 | 7.4 | G | 45 |
BECOPAD 550 | 2.0 – 3.0 | 570 | 14.0 | H | 55 |
BECOPAD 580 | 8.0 – 10.0 | 3571 | 87.6 | I | 58 |