Knowledge Search
Function
Particle counter, water saturation
System
On-/Off-line measuring
Contamination classes
ISO 4406:99, NAS 1638, SAE AS 4059

Core features

  • Optical particle counting via laser sensor
  • Precise evaluation of contamination classes according to
    ISO 4406:99, NAS 1638 and SAE AS 4059
  • Measurements are displayed as particle numbers according
    to contamination classes, water saturation, temperature and
    theoretical water content (ppm)
  • Different automated measuring programs for single,
    continuous, cyclical as on-line measurements
  • Rechargeable lithium polymer battery
  • Internal memory for storing results (capacity up to 100,000 measurement points)
  • Transfer of saved measured values via USB disk
  • LabVIEW data manager software (export to Microsoft Excel)
    for data management on an external computer
  • A thermal printer is optionally available

How It Works - CCS 5 Contamination Monitoring System - Eaton Filtration

Specifications
0
Sort By
()

Specifications

Operating parameters
Power supply: 15 VDC/6 A/90 VA
Power supply
(external unit):
100 to 240 VAC/50/60 Hz/15 VDC/6 A
Protection class: IP 67 (when cover is closed)
Operating suction range: -0.2 to 0.2 bar
Operating pressure range: 1.5 to 350 bar
Viscosity: 10 to 400 mm2/s
Fluid temperature: 0 to 70 °C
Ambient temperature: 0 to 50 °C
 
Measurement parameters
Automatic particle counting in 8 channels: ≥ 4.0 μm(c), ≥ 6.0 μm(c), ≥ 14 μm(c), ≥ 21 μm(c)
Contamination classes: ISO 4406:99, NAS 1638, SAE AS 4059
Laser sensor calibration: ISO MTD in oil (ISO 11171:1999)
Accuracy: ±1 (contamination class)
Water saturation: 0 to 100%
Temperature: 0 to 70 °C
Download Links
Download document () of 20
X
Download Close